GCX SystemView

Camera and Device HealthCheck

Nothing Fails Quietly.

GCX SystemView is the reliability layer of GCX One. Camera HealthCheck verifies that every camera is reachable, streaming and delivering a usable image; Device HealthCheck extends the same supervision to the rest of the connected estate — panels, IoT devices and actors. A failed check is not a line in a log: it raises a technical alarm that can call a technician, send an SMS, escalate, or open a support ticket automatically.

Datasheet · v1.0 · verified 15 September 2026

DatasheetAutomated health monitoring for cameras and connected devices

How GCX SystemView works. Step 1, Schedule: Every 12 hours, every 15 minutes, or on demand. Step 2, Capture: Connect to the live stream and take a snapshot. Step 3, Analyse: Reachable, streaming, lit, unobstructed, untampered. Step 4, Act: Technician call, SMS, escalation or a ticket. Step 5, Prove: A timestamped report the customer can keep.

Key capabilities

  • Continuous verification that each camera is reachable and returning a valid image, on a schedule or on demand
  • Image condition analysis for low light, glare, obstruction, tamper and tilt in the Advanced tier
  • Settings applied at any hierarchy level and inherited downward, so new hardware is covered on arrival
  • A failed check enters the alarm workflow like any other alarm, with escalation and an audit trail
  • Scheduled health reports for customers, supporting SLA validation and compliance review

Primary use cases

  • Estates large enough that manual spot-checks have stopped being credible
  • Vandalism-prone locations, where tamper and obstruction are the real failure mode
  • Proving to a customer that their cameras were working, on a date, in writing
  • Suspending checks during planned maintenance so the work does not generate its own alarms

Performance at a glance

20,000+

Devices scanned per check cycle

12x

Faster than manual checking

65+ hrs

Freed per month

5

Configuration levels

Reactive

Camera HealthCheck Basic

  • Verifies the camera is online and returning a valid image
  • Runs automatically every 12 hours

Proactive

Camera HealthCheck Plus

  • Everything in Basic, plus per-site reports and on-demand checks
  • Frequency from every 15 minutes to every 4 hours

Predictive

Camera HealthCheck Advanced

  • AI image analysis: tamper, tilt, obstruction, glare, low light
  • Flexible check frequency and an interactive dashboard
  • Licensed per camera stream

Estate-wide

Device HealthCheck

System supervision across cameras, panels and IoT devices from one dashboard, flagging connection failures, black screens and low-light feeds.

  • Best for: knowing the whole estate is up, not only the cameras

Architecture

Where the checks run. GCX SystemView connects Cameras, Recorders & panels, IoT & actors to Alarm workflow, Operators, Customer reports.

Measurable results

Measurable results. Effort per month, 20,000 cameras: Manual checking 70 hrs, GCX SystemView 6 hrs — 12x faster. 20,000+ Devices per check cycle , Proven on fleets across 2,900+ sites. 65+ hrs Freed every month , Time returned to the operations team. 5 Configuration levels , Provider, customer, site, device, sensor.

Technical specifications

Camera HealthCheck tiers

Basic
Verifies the camera returns a valid image. Runs every 12 hours. Reactive
Plus
Everything in Basic plus on-demand checks and per-site reporting. Every 15 minutes to 4 hours. Proactive
Advanced
Everything in Plus plus AI image analysis and anomaly detection. Flexible frequency. Predictive. Licensed per camera stream

What a check does

Sequence
Connects to the live stream, captures a snapshot, analyses it against the configured checks, records a verdict, displays it
Basic and Plus Checks
Reachability, streaming status, valid image
Advanced-Only Checks
Low light or no connectivity, no video signal or licence errors, audio-only device recognition, test-pattern and calibration screens, overexposure or glare, blocked or obstructed view, tampering or tilt
Tamper Detection
Disabled by default, requires reference images, and cannot run at the same time as obstruction detection
Camera Status
Healthy shown green; Failed, Unavailable and No Reference Image all shown red and distinguished only by their label

Device HealthCheck

Scope
Supervision across the connected estate — cameras, panels, IoT and actor connections — from one dashboard
Flags
Connection failures, black-screen cameras, low-light cameras
Scale
Proven on fleets above 20,000 cameras across more than 2,900 sites

Alerting and reporting

Alarm Actions
Call Technician, Send SMS or Email, Escalate Alarm, Create Support Ticket
Configuration Levels
Service Provider, Customer, Site, Device, Sensor — a subscription at a parent level cascades to hardware added later
Reports
System HealthCheck and Customer Success reports, schedulable Daily, Weekly, Bi-Weekly or Monthly
Tags
21 default labels, extensible, with names, colours and icons; used to filter the dashboard, scope reports, and exclude cameras under maintenance with automatic reactivation

Governance & Limitations

Thermal Support
White-hot and black-hot modes only; colorised RGBT thermal is not supported
Configuration Dependency
Camera type, thermal versus optical, must be set correctly or results are not accurate
Masking Required
Any blacked-out or blurred region must be masked so it is excluded from the check
Known False Positives
Unnatural angles, and cameras facing untextured or empty space, are flagged unhealthy. Fisheye lenses are not supported

Getting started

Subscribe a tier from the Marketplace, then enable it at the hierarchy level you want covered; everything below inherits it.

  1. 01SubscribeChoose Basic, Plus or Advanced from the Marketplace under Analytics
  2. 02Scope itEnable the check at Customer level so every site and device onboarded later is covered automatically
  3. 03Wire the alertsSet what a failure does: technician call, SMS or email, escalation, or a support ticket
  4. 04Schedule the reportSet the System HealthCheck report to the cadence the customer expects to receive it

Works with

Works with the cameras you already have. axis, dahua, hikvision, milestone, hanwha-techwin, axxon, avigilon, mobotix, vivotek, onvif.
Read the full guide