  1. Introduction
  2. Geutebrück Configuration
  3. Geutebrück Config Guide with GCXONE
  4. Troubleshooting

Introduction

This guide describes the steps required to integrate Geutebrück with the GCXONE platform. Geutebrück is a professional Video Management System (VMS) that provides recording, live viewing, video playback, and event/alarm management for connected cameras and security hardware. GCXONE integrates directly with Geutebrück, allowing streams and events from G-Core servers to appear alongside other devices in the GCXONE platform.

Web API Interface (HTTPS)

Port 13333

RTSP Streaming

Port 554

Applications

• G-Set: system configuration client — used to add hardware, configure media channels, and set up event and behaviour rules.

• G-View: operator client for live viewing, playback, and event monitoring.

• GPLC Simulator: PLC test simulator for I/O and manual event workflows, used during testing.

Geutebrück Configuration

A. Starting G-Core

G-Core is the server component of Geutebrück. It must be running before G-Set or G-View can connect. Start it from the Command Prompt as Administrator:

  1. Open Command Prompt as Administrator.
  2. Navigate to the G-Core installation folder: cd %gngpath%
  3. Stop any running instance: GCoreServer.exe stop
  4. Start G-Core — use Demo mode for testing (GCoreServer.exe demo) or Licensed mode for production (GCoreServer.exe start).
G-Core running in Demo mode — server started and connected to the SQL database.

G-Core running in Demo mode — server started and connected to the SQL database.

B. Connecting G-Set to the Server

Once G-Core is running, launch the G-Set client and connect to the server using the Connection Wizard.

Step 1: Open G-Set. Click Connection Wizard on the main screen.

G-Set main screen — click Connection Wizard to begin.

G-Set main screen — click Connection Wizard to begin.

Step 2: Enter the Connection name, Host name (G-Core server IP), Username, and Password. Default credentials: username = sysadmin, password = masterkey. Click Ping Host and Check Connection to verify, then click OK.

Connection Wizard form — enter host details and verify connectivity before saving.

Connection Wizard form — enter host details and verify connectivity before saving.

Step 3: In the Connections panel, right-click the connection and select Connect.

Right-click the connection name and select Connect to establish the session.

Right-click the connection name and select Connect to establish the session.

C. Adding Hardware (IP Camera)

Hardware in G-Set represents the physical camera device. Each camera is added as an IP-Camera plugin module.

Step 1: In the left panel, expand Media channels / Hardware and click Hardware.

Step 2: In the Hardware module list, right-click and select Add.

Hardware module list — right-click and select Add.

Hardware module list — right-click and select Add.

Step 3: In the Add hardware module dialog, select IP-Camera Plugin <ONVIF IPC> and click Add.

The Add hardware module dialog in Geutebrück G-Set with the ONVIF IPC plugin highlighted among the camera plugins, and the Add button marked.

Select IP-Camera Plugin <ONVIF IPC> and click Add.

Step 4: Configure the hardware module and click Save:

Name

Descriptive name for the module (e.g., SCT-Entrance)

Hostname

IP address of the camera

Username

Camera login username

Password

Camera login password

Hardware configuration panel — enter camera name, hostname, and credentials.

Hardware configuration panel — enter camera name, hostname, and credentials.

D. Adding a Sensor (Media Channel)

A media channel in G-Set is what GCXONE recognises as a sensor. It links a video stream from a hardware module to the GCXONE device.

Step 1: In the left panel, click Media channels under Media channels / Hardware.

Step 2: Right-click in the list and select Add.

Media channel list — right-click and select Add.

Media channel list — right-click and select Add.

Step 3: In the Module channels dialog, select the hardware module you just created and click Add.

Module channels dialog — select the hardware module (e.g., Module channel 1 on <SCT-Entrance>) and click Add.

Module channels dialog — select the hardware module (e.g., Module channel 1 on <SCT-Entrance>) and click Add.

Step 4: Enter the channel details and click Save:

Name

e.g., SCT-Entrance

Description

e.g. This is entrance camera

Geutebrück G-Set media channel configuration, with the Name and Description fields for SCT-Entrance highlighted above the media channel source and numbering settings.

Media channel settings — enter the channel name and description.

Step 5: Select the channel in the tree, open Permanent recording, enable it, and click Save. The sensor is now added and linked.

Permanent recording enabled for the media channel.

Permanent recording enabled for the media channel.

G-View Application

G-View is the operator client used to watch live feeds, review recorded footage, and monitor events.

Step 1: Launch G-View. In the Video servers panel, right-click the server name and select Connect.

G-View — right-click the server and select Connect.

G-View — right-click the server and select Connect.

Step 2: Expand the server tree. Double-click a media channel to open its live stream.

Step 3: Use the playback controls and the Event / MOS timeline tabs to review recorded footage and jump to event markers.

Geutebrück G-View playing back footage from the SCT-Entrance camera, with the channel highlighted in the tree on the left and a timeline and transport controls below.

G-View live feed — SCT-Entrance channel streaming with timeline visible.

Geutebrück Config Guide with GCXONE

A. Add a Geutebrück Device

Register the Geutebrück G-Core server as a device under the target site.

Step 1: Navigate to the target site in the Configuration app, open the Devices tab, and click Add New.

Site Devices tab — click Add New to register a new Geutebrück device.

Site Devices tab — click Add New to register a new Geutebrück device.

Step 2: In the Add Device dialog, open the Device dropdown and select Geutebrueck, then enter all required fields: Name, IP Address or Host, User Name, Password, Server Port, HTTPS Port, RTSP Port, Control Port. Server Port, HTTPS Port, and RTSP Port default to 13333, 13333, and 554 respectively, matching G-Core's default configuration.

The Add Device dialog with Geutebrueck chosen, showing the name field and connection settings for address, credentials, server port, HTTPS port and RTSP port.

Add Device dialog — select Geutebrueck as the device type and fill in the server connection details.

Step 3: Below the connection fields, the dialog also has a Select Entity Group dropdown, an Enable Audio toggle (on by default), a required Timezone, a Device Configuration section (Site Pulse Configuration), an Advanced Settings section (Event Polling, Configure Heatmap Mask, Periodic Health Check, Event Retention Time — 30 days by default), and an optional Location section (Latitude, Longitude, Plus Code, What3Words).

Step 4: Click Discover to confirm GCXONE can reach the device, then click Save.

B. Verify the Live Stream in GCXONE

Once saved, sensors from G-Set appear under the device in GCXONE. Open any sensor in the Video Viewer to confirm the live stream is active.

GCXONE Video Viewer — live stream from the Geutebrück-connected camera confirmed.

GCXONE Video Viewer — live stream from the Geutebrück-connected camera confirmed.

Event Rule Configuration in G-Set

Event rules define what triggers an alarm, how the system responds, what is recorded, and how the alarm appears in G-View and GCXONE. The Event/Alarm Wizard guides you through five steps.

To open the wizard: in G-Set navigate to Events / Behaviour Rules → Events, right-click in the event list and select Add.

Step 1 — Event Settings

Enter the event name, configure timing, and set database storage options.

•Event name: enter a descriptive name (e.g., VMD event).

•Retrigger mode: set to Retrigger to allow the event to restart while already active.

•Store to database: ensure On start and On stop are enabled so events appear in logs.

Step 1 — Event Settings. Configure the event name, ring buffer, retrigger mode, and database logging.

Step 1 — Event Settings. Configure the event name, ring buffer, retrigger mode, and database logging.

Step 2 — Action Settings

Define which alarm actions start and stop the event by dragging items from the Action list into the Start by and Stop by zones.

•Start by: G-Tect/VMD alarm — triggers the event when motion is detected.

•Stop by: G-Tect/VMD alarm finished — ends the event when motion stops.

The Action settings step in Geutebrück G-Set, with a G-Tect VMD alarm as the start trigger and the action list open on G-Tect/VMD alarm finished.

Step 2 — Action Settings. G-Tect/VMD alarm assigned as the Start action. The Action list shows all available triggers.

Step 3 — Recording Settings

Assign the media channels to record when the event fires by dragging them from the channel list into the Recording channels drop zone.

Step 3 — Recording Settings. SCT-Entrance is available in the media channels list.

Step 3 — Recording Settings. SCT-Entrance is available in the media channels list.

Step 4 — Alarm Settings

Configure the alarm that appears in G-View and GCXONE when the event fires.

•Alarm name: e.g., test or VMD alarm.

•Alarm priority: High, Medium, or Low.

•Media channels: drag the camera channel so the alarm opens its feed automatically.

•Default alarm scene: enable to display the camera when the alarm is acknowledged.

Step 4 — Alarm Settings. Alarm name, priority, and associated media channel are configured.

Step 4 — Alarm Settings. Alarm name, priority, and associated media channel are configured.

Step 5 — Summary

Review the complete configuration in one table, then click Save & Finish to commit the event rule.

Step 5 — Configuration Summary. VMD event with G-Tect/VMD alarm trigger, SCT-Entrance recording, and test alarm confirmed.

Step 5 — Configuration Summary. VMD event with G-Tect/VMD alarm trigger, SCT-Entrance recording, and test alarm confirmed.

Reviewing the Event Configuration

After saving, clicking an event in the G-Set Events tree opens its full configuration — including the event tree, recording task, media channels, and playback profile.

Event configuration detail — VMD event tree showing Recording tasks, StartBy, StopBy, and recording profile at 25 fps on SCT-Entrance.

Event configuration detail — VMD event tree showing Recording tasks, StartBy, StopBy, and recording profile at 25 fps on SCT-Entrance.

Note: Once events are saved in G-Set, they are automatically transmitted to GCXONE via the device integration. No additional configuration is required in GCXONE to receive Geutebrück events — they appear in the GCXONE event log alongside other device events.

Troubleshooting

Viewing Event Logs in G-View

All triggered events are logged in the G-View Event list. A populated log confirms the device is online and events are being captured correctly.

Step 1: Open G-View and connect to the server.

Step 2: In the top menu bar, click View then select Event list.

G-View — View menu with Event list highlighted.

G-View — View menu with Event list highlighted.

Step 3: The Event list opens. Each entry shows:

Start time

Timestamp when the event was triggered

Event name

Name assigned in Step 1 of the Event Wizard

Stop time

Timestamp when the event ended

Text / Description

Description text set in the event configuration

G-View Event list — VMD events logged with start time, stop time, event name, and description. A populated log confirms end-to-end integration.

G-View Event list — VMD events logged with start time, stop time, event name, and description. A populated log confirms end-to-end integration.

A populated event log confirms that events configured in G-Set are successfully captured, stored, and visible in G-View — validating the complete Geutebrück integration from device to GCXONE.

For technical support or integration assistance, contact NXGEN Technology AG through the GCXONE support portal.

Was this page helpful?

Thank you — your feedback goes to the team that owns this page.

Release notes

Know when something ships

New features, fixes and integration updates for GCXONE, delivered to your inbox as they are released.

We send a confirmation link first. Every message has an unsubscribe link.